A heat pump not heating your home is one of the most frustrating things you can deal with, especially when the outdoor unit is running, the fan is blowing, and the air coming through the vents feels like nothing at all. The thermostat is set to 70°F. The room reads 61°F. And nothing about the situation makes sense.
Here is what matters most before you do anything else: most heat pumps that stop delivering warm air have a diagnosable, fixable cause. Several of them take under five minutes to resolve without calling anyone. Knowing the difference between a quick homeowner fix and a situation that requires professional heat pump installation& repair is exactly what this guide is built to help you figure out.
You will find the six most common causes of a heat pump that stops heating, a step-by-step diagnostic sequence you can run right now, and a clear decision point between what is safe to handle yourself and what requires a NATE-certified professional.
McCormick Heating & Cooling has been diagnosing and repairing heat pumps across Northern Colorado since 2004. If you have already worked through the basics and your system still is not responding, our team is ready to help.Schedule a same-day service appointment online or call us directly! We service Loveland, Greeley, Fort Collins, and the surrounding communities throughout Larimer and Weld County.
What Your Heat Pump Should Actually Feel Like in Winter
Most homeowners who call about a heat pump not heating have never had normal heat pump behavior explained to them. Once you understand the baseline, several alarming symptoms stop sounding like emergencies.
Why Heat Pump Air Feels Different Than Furnace Air
A gas furnace produces supply air at 120°F to 140°F at the register. A heat pump in heating mode typically delivers air at 90°F to 100°F at the same register. That output will raise indoor temperature steadily, but it is noticeably cooler than furnace output, and that difference is not a malfunction. It is the fundamental design distinction between the two technologies.
Heat pumps move heat from outdoor air into your home rather than generating heat through combustion. At 35°F outside, a properly sized and properly charged heat pump delivers roughly 2.5 units of heat energy per unit of electricity consumed, a coefficient of performance (COP) of approximately 2.5. As outdoor temperatures drop toward 25°F, that ratio shrinks and the system works harder for smaller output gains.
If supply air feels "not as hot as a furnace," that perception is usually accurate and normal. If air at the register is cold or sitting at room temperature, and your thermostat cannot reach its set point by two or more degrees, one of the six causes below is the most likely explanation.
The 6 Reasons a Heat Pump Stops Heating
1. Wrong Thermostat Mode or Fan Setting
This is the most common cause and the most frequently overlooked. If the thermostat was switched to "Cool" or "Fan Only" mode, the system will run exactly as commanded: the outdoor unit operates, the fan moves air, and the house gets colder.
Check this first. Set the thermostat to "Heat" mode and confirm the fan is set to "Auto," not "On." When the fan is set to "On," it runs continuously, including the minutes between heating cycles when the heat exchanger has cooled down. Unheated air blows through your vents on a repeating schedule, and the symptom looks exactly like a system that has stopped producing heat.
Switching the fan to "Auto" means it only runs during an active heating cycle. Many homeowners who recently moved into a home, had a thermostat replaced, or had settings bumped during a power outage have resolved a full "no heat" situation with this single adjustment.
To confirm: Set the thermostat 3°F to 5°F above the current room temperature and wait five minutes. Warm air flowing from the vents confirms the thermostat mode was the cause.
When outdoor temperatures drop below 35°F, atmospheric moisture freezes onto your exterior coil. To prevent ice buildup, your heat pump automatically triggers a defrost mode that temporarily reverses refrigerant flow to melt the frost.
During this 5- to 15-minute cycle, vents may blow lukewarm air while the outdoor unit hisses or releases steam. In freezing weather, this routine activates every 30 to 90 minutes. If normal heating resumes within 15 minutes, your equipment is operating properly.
On Daikin variable-speed inverter units, the exterior fan stops completely during defrosting, and indoor vents deliver cool air for 2 to 4 minutes. Homeowners often mistake this brief temperature drop for a breakdown, though it is standard operation.
When to take action: Proceed to Cause 3 if defrosting lasts longer than 30 continuous minutes or if solid ice coats the exterior coil.
3. The Outdoor Unit Is Frozen Beyond a Normal Defrost Cycle
While light morning frost is normal, a solid block of ice encasing the exterior coil fins or base pan stops heat extraction completely by blocking airflow.
Severe freezing typically stems from:
A clogged MERV 8 to 13 air filter restricting indoor circulation
Low refrigerant levels dropping suction-side pressure and freezing the coil
A faulty defrost control board failing to initiate thawing cycles
Heavy snow or yard debris obstructing the exterior cabinet
What you can do: Set your thermostat to "Fan Only" for 30 to 60 minutes for passive thawing, clear 24 inches of space around the outdoor cabinet, and replace filters older than 90 days. Never pour hot water onto iced coils, as thermal shock cracks delicate metal fins and refrigerant lines.
If heavy ice returns within two hours, call a licensed technician to repair refrigerant leaks or defrost controls. For more Larimer County winter insights, read our blog post, Heat Pump Frozen? Ice on the Outdoor Unit Explained.
4. Low Refrigerant Charge or a Refrigerant Leak
Refrigerant is not consumed during normal heat pump operation. A sealed system holds its charge for the life of the equipment. If refrigerant is low, a leak exists somewhere in the circuit, and that leak must be found and repaired before recharging has any lasting value.
Low refrigerant affects a heat pump in two simultaneous ways. First, reduced refrigerant mass flow cuts the system's ability to extract and transfer heat, so output drops even though the compressor is running at full speed. Second, reduced refrigerant lowers suction-side pressures, which drops coil temperatures and drives the abnormal ice formation described in Cause 3.
Symptoms that point to a refrigerant issue:
The system runs continuously but cannot reach the thermostat set point
Outdoor coil ice that returns after each completed defrost cycle
A faint hissing or bubbling sound near the indoor air handler or along the refrigerant line set at the outdoor unit
Utility bills rising without any change in thermostat settings or occupancy patterns
Refrigerant handling requires EPA608 certification. This is not a homeowner repair. A McCormick technician will pressure-test the refrigerant circuit, locate the leak, complete the repair, and recharge to manufacturer-specified levels. Most systems installed before 2025 use R-410A. Newer equipment uses R-32 or R-454B, both of which require different handling procedures and carry lower global warming potential ratings.
5. A Reversing Valve That Has Stuck or Failed
The reversing valve is the component that makes a heat pump reversible. It controls the direction of refrigerant flow, shifting the system between heating and cooling operation based on a signal from the thermostat. When the valve sticks in the cooling position or fails to shift on command, the system runs in cooling mode regardless of what the thermostat calls for. The compressor runs, the fan moves air, and cold or room-temperature air comes out because the system is actively cooling your home while you are trying to heat it.
Signs that point to a reversing valve problem:
The system actively cools the home when the thermostat is set to "Heat"
Supply air temperature at the register is at or below room temperature during a heating call
In a classic reversal failure, the system heats correctly when set to "Cool" and cools when set to "Heat"
Diagnosing a reversing valve issue requires refrigerant circuit pressure measurements taken across both operating modes. The repair itself is straightforward, but it requires refrigerant recovery, proper handling equipment, and EPA 608 certification. This is a technician call, not a homeowner fix.
6. Outdoor Temperature Beyond Your System's Rated Operating Limit
Standard air-source heat pumps deliver full capacity at 47°F and maintain functional warmth down to 25°F. Below 20°F, standard models require supplemental heating to keep your house comfortable. With January overnight lows averaging 18°F and winter cold fronts dropping below 0°F, unassisted equipment quickly reaches its operational limit rather than experiencing a mechanical failure.
When room temperatures slip 2°F to 3°F below your target, the thermostat automatically engages electric resistance heat strips inside the air handler. Verify your thermostat stays in "Heat" mode rather than "Emergency Heat," which shuts down the exterior compressor and relies entirely on expensive resistance strips.
While standard units lose significant capacity below 17°F and bottom out near -4°F, specialized systems like the Daikin Aurora series operate down to -13°F. If your cold-weather model struggles during mild temperatures, review Cause 4 or Cause 5. For regional performance metrics, explore our guide onCold Climate Heat Pumps in Fort Collins, CO.
Why Heat Pumps Work Harder Here and What That Looks Like
The Elevation Impact at 4,982 Feet
Loveland sits 4,982 feet above sea level, where air density drops by roughly 17%. Because thinner air holds less thermal energy, HVAC systems lose about 3% of their rated heating capacity per 1,000 feet of elevation. Locally, this creates a 15% output reduction compared to sea-level test ratings. A 36,000 BTU/h unit actually delivers between 30,600 and 33,000 BTU/h in Loveland. If your installer skipped an altitude correction during the Manual J load calculation, your unit may struggle on freezing nights despite having no broken components.
Rapid Temperature Swings and Auxiliary Heat
Northern Colorado experiences drastic weather shifts. An afternoon at 52°F near Benson Sculpture Garden can plunge to 18°F by midnight as mountain cold fronts roll in. When outdoor temperatures plummet that fast, your primary unit cannot ramp up quickly enough to maintain the indoor target. Once room temperatures dip 2°F to 3°F below your setting, the thermostat triggers auxiliary heat strips to bridge the gap. For homeowners near Boyd Lake, brief auxiliary activation during sudden freezes is normal operation. However, if auxiliary heat runs nonstop for over 24 hours or causes persistent winter utility spikes, your primary heat pump needs professional inspection.
The Diagnostic Sequence: What to Check Before Calling Anyone
The 5-Minute Homeowner Checklist
Work through these steps in order before scheduling a service call:
Thermostat mode: Confirm the setting is "Heat," the fan is "Auto," and the set point is at least 3°F above current room temperature.
Air filter: Pull the filter and hold it to a light source. If light does not pass through clearly, replace it before running the system further. A loaded MERV 13 filter restricts airflow enough to cause coil freezing and a sharp drop in heating output.
Outdoor unit: Check for snow or debris blocking airflow. Maintain a 24-inch clearance on all sides. Distinguish between light frost (normal) and solid ice encasing coil fins or the base pan (a problem that needs action).
Breaker panel: Confirm both the air handler breaker and the outdoor unit breaker are fully in the "On" position. A half-tripped breaker can power the fan while killing the compressor, producing the exact "fan on, no heat" symptom with no other visible indicator at the unit itself.
System reset: Follow the reset sequence in the section below if all four steps above check out but the system still is not producing heat.
Symptom-to-Cause Quick Reference
Symptom
Most Likely Cause
DIY Step
Call a Technician If...
Lukewarm air for 5 to 15 minutes
Normal defrost cycle in progress
Wait and monitor
Defrost-like state continues for 30 or more minutes
Cold air from vents, fan running
Fan set to "On" or wrong thermostat mode
Set fan to "Auto," confirm "Heat" mode
Problem continues after the adjustment
Thick ice on outdoor unit
Clogged filter, blocked airflow, or low refrigerant
Replace filter, clear debris from unit perimeter
Ice returns within 2 hours of clearing
Fan running, no heat whatsoever
Reversing valve failure or low refrigerant
Confirm thermostat mode first
Mode is correct and problem still persists
Runs constantly, cannot reach set point
Below rated operating temp or low refrigerant
Check outdoor temp against system spec
Indoor temp is actively dropping, not holding
Tripped circuit breaker
Electrical overload or short
Reset once at the panel
Breaker trips again immediately after reset
The "Stop Here and Call" Line
Stop the checklist and contact a technician immediately if any of these conditions are present:
The circuit breaker trips again after a single reset attempt
You hear clicking, grinding, or squealing coming from the outdoor unit
There is a burning smell from any supply register or from the air handler cabinet
Thick ice has returned to the outdoor coil within two hours of clearing
Indoor temperature is actively dropping rather than holding at the set point
For heat pump repair and installation service across the Northern Colorado area, McCormick Heating & Cooling's NATE-certified team is available for same-day appointments. Visit ourheat pump repair and installation page or call (720) 217-4801.
Should You Switch to Emergency Heat Right Now?
Emergency heat, labeled "EM Heat" on most thermostats, bypasses the outdoor heat pump unit entirely and runs only the electric resistance heating strips inside the air handler. It will warm the home, but it draws significantly more energy than normal heat pump operation at moderate outdoor temperatures and should not be used as a routine setting.
Use EM Heat if: The outdoor unit has a confirmed mechanical failure such as a locked compressor or persistent grinding noise, a technician has directed you to isolate the outdoor unit while a replacement part is sourced, or outdoor temperatures have dropped below -10°F and your system is a standard (non-cold-climate) heat pump.
Do not use EM Heat as a default cold-weather setting. Many homeowners switch it on thinking it will boost heat output on cold nights. What it actually does is shut down efficient heat pump operation and replace it with high-consumption resistance heating. On a night when it is 20°F outside and your heat pump is functional, running EM Heat draws significantly more energy for the same level of indoor comfort a properly operating heat pump would already deliver.
For the complete explanation of what the EM Heat setting does, when your thermostat activates it automatically, and when manually switching it on is the right call, see our detailed guide onwhat EM heat means on a heat pump thermostat.
How to Properly Reset Your Heat Pump
The Two-Step Power Cycle Process
A system reset clears stored fault codes from the control board and can resolve minor electrical glitches that cause a heating lockout. Follow this sequence exactly:
Step 1: Set the thermostat to "Off." Do not switch it to "Cool" or "Fan Only." Set it fully to "Off" and wait 60 seconds.
Step 2: Go to the breaker panel and switch the heat pump breaker to "Off." If the air handler is on a separate circuit, switch that one off as well. Wait 30 seconds, then switch both back to "On."
Step 3: Return to the thermostat, set it to "Heat," and raise the set point 3°F above current room temperature. Allow 5 to 10 minutes for the full startup sequence to complete. Inverter-driven systems, including Daikin variable-speed models, intentionally ramp up from a low starting compressor speed over 3 to 8 minutes. Initial output during startup will feel lukewarm. That is normal inverter startup behavior and is not an indication that the reset failed.
Critical note: If normal heating does not return after one reset cycle, do not repeat the process. Additional resets erase the fault codes a technician needs to identify the problem quickly. Make the call after one unsuccessful attempt.
A heat pump running without producing heat is most often caused by a thermostat set to "Cool" or "Fan Only" mode, a reversing valve stuck in cooling position, low refrigerant charge, or outdoor temperatures that have exceeded the system's rated operating range. Start with the thermostat check and work through the 5-minute homeowner checklist above. Most causes can be confirmed or eliminated in under five minutes without any tools.
Cold air from a heat pump set to "Heat" has three common causes: the thermostat fan set to "On" blowing unheated air between active heating cycles; a defrost cycle temporarily active that will clear within 15 minutes; or a reversing valve that has failed and locked the system into cooling operation regardless of the thermostat setting. The first two causes are self-correcting or resolved with a simple thermostat adjustment. A failed reversing valve requires a licensed technician.
Standard air-source heat pumps lose significant heating capacity below 25°F to 30°F and typically cannot maintain indoor comfort as the sole heat source when outdoor temperatures fall below 20°F. In this region, where January overnight lows average 18°F and cold snaps regularly push below 0°F, a cold-climate model or a dual-fuel system delivers the most reliable year-round performance. See ourcold-climate heat pump guide for Northern Colorado for model-specific performance comparisons at local design temperatures.
Yes. During cold weather, continuous operation is expected and efficient. Heat pumps are designed for long, lower-intensity run cycles rather than the short, high-output bursts of a gas furnace. During sustained outdoor temperatures below 30°F, a heat pump may run for hours at a stretch while holding the indoor set point, and that is correct operation. The pattern that signals a problem is a home temperature that is actively dropping despite continuous system operation, which points to an undersized system, low refrigerant, or a temperature range issue.
Use EM Heat only when the outdoor unit has a confirmed mechanical failure or a technician has directed you to isolate it. Activating EM Heat prematurely replaces efficient heat pump operation with high-consumption resistance heating and provides no performance benefit when the heat pump itself is functional. For the full breakdown of when EM Heat is the right call, see our guide onwhatEM heat means on your thermostat.
Set the thermostat to "Off," switch the heat pump breaker at the electrical panel to "Off," wait 30 seconds, then switch it back to "On." Return the thermostat to "Heat" mode with the set point 3°F above the current room temperature and allow up to 10 minutes for the startup sequence to complete. If normal heating does not return after one reset attempt, contact a technician rather than repeating the process. Additional resets erase the fault code history needed for fast, accurate diagnosis.
Yes, and this is a detail many homeowners in this area never hear about. At 4,982 feet above sea level, air density is approximately 17% lower than at sea level. Using the industry-standard 3% derating per 1,000 feet of elevation, a heat pump rated at 36,000 BTU/h at standard sea-level test conditions may deliver only 30,600 to 33,000 BTU/h of actual output locally. If a system was sized without applying an altitude correction to the Manual J calculation, it may be technically functional but consistently short on capacity during peak winter demand.
Schedule Heat Pump Service in Northern Colorado
If you have worked through the checklist above and are still dealing with a heat pump not heating, the cause is most likely a refrigerant leak, a reversing valve failure, or a control board fault. None of those conditions are safe or practical to address without EPA 608 certification and proper refrigerant recovery equipment.
McCormick Heating & Cooling has served Northern Colorado homeowners since 2004. Our NATE-certified technicians are based in Greeley and service the Loveland area regularly, including homeowners near Boyd Lake, Boyd Lake North, the Benson Sculpture Garden neighborhood, Lakes at Centerra, and throughout Larimer County. Same-day service, after-hours emergency response, and a 100% satisfaction guarantee back every job we complete.
About Jesse Trout - Owner of McCormick Heating & Cooling
Colorado Native. HVAC Expert.
Jesse Trout is the owner of McCormick Heating & Cooling, the family-owned HVAC company that has served Greeley and Northern Colorado since 2006. A Colorado native and HVAC expert, Jesse leads the team of installers, service technicians, and front office staff who keep Northern Colorado homes comfortable year-round.